| | Click on the link to bring up the search window | Goto Outgassing Search Do a search for a
material or manufacturer or product type or chemical nature. A few letters of the name are required to bring up a list of materials, manufacturers, product or chemicals. After selection of one the test results are displayed. |
|
|
| | | Mass of material concerned,(grams) | CVCM(%)
| RML(%) | >1000 | <0,01 | <1 | 100–1000 | <0,01 | <1 | 10–100 | <0,01 | <1 | 1–10 | <0,03 | <1 | <1 | <0,1 | <1 |
|
| | | For stringent CVCM requirement one shall consider that the CVCM detection limit for a standard micro-VCM test is around 0.02% because of both material variance ands and measuring errors. For cases where CVCM <0.05% or less is required, improved sensitivity CVCM shall be
implemented, such as use of quartz crystal micro-balance as a fourth collector plate or determination of mass by infrared transmission data. |
|
| | | MITIGATION: Mitigation techniques, such as baking, application of protective coating or shielding, can be applied in order to protect against or remove residual contaminants, process contaminants and handling contaminants.
VARIANCE IN OUTGASSING: Variability in materials composition or process parameters may cause a large spread in outgassing
results. This can induce a need for a retest or batch to batch test.
AGE OF LAST TEST RESULT: If the material is tested more than 10 years ago at the time of PDR, new test is required for application. If the most recent test is older than 7 years, new test recommended.
|
|